Jlg 340AJ Service Manual User Manual Page 314

  • Download
  • Add to my manuals
  • Print
  • Page
    / 348
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 313
SECTION 6 - JLG CONTROL SYSTEM
6-70 – JLG Lift – 3121259
Table 6-11. Overload Variations
BROADCAST ONLY
3
WARN ONLY CUTOUT ALL
SPECIAL 1
(Access Industries)
CUTOUT PLATFORM
Platform
Activate visual overload light at
Platform Station
Activate visual overload light at
Platform Station
Activate System Distress and Over-
load lights at Platform station
Activate visual overload light at
Platform Station
Activate System Distress and
Overload lights at Platform sta-
tion
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– on continuously
Activate Platform and Ground
Alarm – 5 sec ON, 2 sec OFF
Do not report Fault Activate creep mode all functions,
energize Creep light, and report
Fault
Do not permit Machine Enable (no
creep light) and report Fault
Activate creep mode all functions,
energize Creep light, and report
Fault
Do not permit Machine Enable
(no creep light) and report Fault
Disable Telescope Out and Lift Up
Ground
Activate visual overload light
(Ground Station)
Activate visual overload light
(Ground Station)
Activate visual overload light
(Ground Station)
Activate visual overload light
(Ground Station)
Activate visual Overload light at
Ground Station
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– 5 sec ON, 2 sec OFF
Activate Platform and Ground Alarm
– on continuously
Activate Platform and Ground
Alarm – 5 sec ON, 2 sec OFF
Do not report Fault Report Fault Report Fault Do not report Fault Do not report fault.
Activate creep mode all functions Do not permit Machine Enable (no
creep light)
Overload shall have no effect on
function speeds.
Overload shall have no effect on
function speeds.
Auxiliary Power/Emergency Descent
Platform operation and annuncia-
tion as Platform Mode above
Platform operation and annuncia-
tion as Platform Mode above
Platform operation and annuncia-
tion as Platform Mode above, except
do not disable all functions
Platform operation and annuncia-
tion as Platform Mode above
Platform operation and annunci-
ation as Platform Mode above,
except do not report Fault or dis-
able all functions
Ground operation and annunciation
as Ground Mode above, except do
not activate creep mode
Ground operation and annunciation
a s G ro un d M od e a bo ve, ex ce pt do
not activate creep mode
Ground operation and annunciation
as Ground Mode above, except do
not report Fault or disable all func-
tions
Ground operation and annunciation
as Ground Mode above
Ground operation and annuncia-
tion as Ground Mode above
Faults
No applicable fault When the platform is overloaded,
report “RUNNING AT CREEP - PLAT-
FORM OVERLOADED.
When the platform is overloaded,
report "DRIVE & BOOM PREVENTED
– PLATFORM OVERLOADED."
When the platform is overloaded,
report "LIFT UP & TELE OUT PRE-
VENTED – PLATFORM OVER-
LOADED.
When the platform is overloaded,
report the "DRIVE & BOOM PRE-
VENTED – PLATFORM OVER-
LOADED."
Clarifications:
1. The term Report Fault is defined as logging the DTC on the Analyzer fault stack and flashing the System Distress lamp.
2. When specified, Ground Alarm energization shall only occur if MACHINE SETUP GROUND ALARM ≠ NO.
3. This selection is not Analyzer configurable in MACHINE SETUP LOAD SYSTEM but is shown here for completeness of the response table.
Page view 313
1 2 ... 309 310 311 312 313 314 315 316 317 318 319 ... 347 348

Comments to this Manuals

No comments