SECTION 6 - JLG CONTROL SYSTEM
6-40 – JLG Lift – 3121259
Table 6-10. Fault Code Troubleshooting Information
Help Message DTC Condition Producing DTC
Control System Response or
Machine Condition
Corrective Action/
Operational Requirement
for Function Movement
and/or to Clear Fault
EVERYTHING OK or
GROUND MODE OK
001
1
The platform station (EVERYTHING OK) or ground station (GROUND
MODE OK) is selected and the system detects no problems exist.
No response required. -
RUNNING AT CUTBACK – OUT
OF TRANSPORT POSITION
0010
1
Tower Elevation Switch shows tower is elevated out of transport
position
or
Boom Elevation Switch #1 shows boom elevated out of transport
position
or
Boom Elevation Switch #2 shows boom elevated out of transport
position
Machine is considered Out Of
Transport Position
Lower boom into transport
position
FSW OPEN
0011
1
Machine is in Platform Mode
Drive/Steer or Boom function control is activated when Footswitch
not engaged
Machine is not allowed to enter
the Machine Enabled state
Release controls, Engage Foot-
switch and reactivate Drive/
Steer and/or Boom function
control
RUNNING AT CREEP - CREEP
SWITCH OPEN
0012
1
Machine is in Platform Mode
Platform creep switch is turned on
Creep Mode is active Turn Platform creep switch off
RUNNING AT CREEP - TILTED
AND ABOVE ELEVATION
0013
1
Fa ul t RUN NING AT CR EEP - CRE EP S WITC H O PEN (DTC 00 12 ) i s n ot
active
Machine is Out Of Transport Position
Machine chassis is considered Tilted
Creep Mode is active Lower Machine and place on
firm, level surface
RUNNING AT CREEP – PLAT-
FORM STOWED
0030
1
Platform is in Stowed Position Lift Down and Level Down
function speed maximums are
limited to Ground Creep
Raise Platform from Stowed
Position
FUEL LEVEL LOW – ENGINE
SHUTDOWN
0031 Engine Shutdown has occurred due to Fuel Level being EMPTY Machine prohibits engine
cranking and throttle functions
Add fuel to fuel tank
APU ACTIVE 0035 Emergency Descent Mode is active Operation specified in Emer-
gency Descent Mode section
Stop using Emergency Descent
Mode
KEYSWITCH FAULTY 212 Both Ground and Platform Keyswitches are energized at the same
time
The Control System assumes a
station selection of Ground
On Analyzer under DIAGNOS-
TICS-->SYSTEM-->PLAT-
FORM SELECT (and GROUND
SELECT), activate Platform and
Ground keyswitches to deter-
mine fault location; then trou-
bleshoot wiring and/or
keyswitch.
FSW FAULTY 213 The ground footswitch input and platform footswitch input have
been both engaged or disengaged for a time period greater than or
equal to 1 second
Machine does not allow any
functions
Use the Emergency Stop Switch
to cycle power
Page view 283