SECTION 6 - JLG CONTROL SYSTEM
3121259 – JLG Lift – 6-67
LSS READING UNDER WEIGHT 8211 MACHINE SETUP LOAD SYSTEM NO
The load sensor has been calibrated and Gross Platform Weight <
(0.5 * Empty Platform Weight).
Ground Module to set Platform
Load State = Overloaded
Not all of the trigger conditions
are met
FRONT LEFT STEER VALVE –
OPEN CIRCUIT
8639 The Ground Module detects an open circuit at the Front Left Steer
Valve output.
Steer Left and Right speed are
limited to Creep
Cycle power to clear the fault.
FRONT LEFT STEER VALVE –
SHORT TO BATTERY
8640 The Ground Module detects a short to battery at the Front Left Steer
Valve output.
The Ground Module disables
the Drive Forward/Reverse and
Steer Left/Right outputs.
Cycle power to clear the fault.
FRONT LEFT STEER VALVE –
SHORT TO GROUND
8641 The Ground Module detects a short to ground at the Front Left Steer
Valve output.
The Ground Module disables
the Steer Left and Right out-
puts.
Cycle power to clear the fault.
FRONT RIGHT STEER VALVE
OPEN CIRCUIT
8642 The Ground Module detects an open circuit at the Front Right Steer
Valve output.
Steer Left and Right speed is
limited to Creep
Cycle power to clear the fault.
FRONT RIGHT STEER VALVE
SHORT TO BATTERY
8643 The Ground Module detects a short to battery at the Front Right Steer
Valve output.
The Ground Module disables
the Drive Forward/Reverse and
Steer Left/Right outputs
Cycle power to clear the fault.
FRONT RIGHT STEER VALVE
SHORT TO GROUND
8644 The Ground Module detects a short to ground at the Front Right Steer
Valve output.
The Ground Module disables
the Steer Left and Right out-
puts
Cycle power to clear the fault.
OSCILLATING AXLE SWITCH
DISAGREEMENT
8669 The Ground Module detects that Oscillating Axle switch #1 and
switch #2 are not in agreement. Note: This fault will not to be
reported if DTC 23104 BOOM TRANSPORT SWITCH DISAGREEMENT is
active.
The Ground Module assumes
an Above Elevation State and
de-energizes J1-7 Oscillating
Axle output.
Cycle power to clear the fault.
LSS WATCHDOG RESET 991 The Ground Module detects an LSS report of an anomaly that has
caused a WatchDog Timer reset.
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
LSS EEPROM ERROR 992 The Ground Module detects an LSS report of an anomaly that exists in
the LSS EEPROM
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
LSS INTERNAL ERROR – PIN
EXCITATION
993 The Ground Module detects an LSS report of improper excitation
voltage.
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
LSS INTERNAL ERROR – DRDY
MISSING FROM A/D
994 The Ground Module detects an LSS report of an anomaly that exists in
the LSS A/D converter operations.
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
EEPROM FAILURE - CHECK ALL
SETTINGS
998 The Ground Module has detected an anomaly in the EEPROM The Ground Module disables all
functions and resets the section
of EEPROM where the failure
occurred back to the defaults.
Cycle power to clear the fault.
Table 6-10. Fault Code Troubleshooting Information
Help Message DTC Condition Producing DTC
Control System Response or
Machine Condition
Corrective Action/
Operational Requirement
for Function Movement
and/or to Clear Fault
Page view 310