SECTION 6 - JLG CONTROL SYSTEM
3121259 – JLG Lift – 6-69
CURRENT FEEDBACK CALI-
BRATION CHECKSUM INCOR-
RECT
9945 The current feedback gains checksum that is calculated and written
to flash memory during manufacturing is detected as being incorrect
All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start).
Cycle power to clear the fault.
MACHINE CONFIGURATION
OUT OF RANGE – CHECK ALL
SETTINGS
9949 The Ground Module has detected an anomaly in stored readings for
the Machine Setup configuration.
The Ground Module prompts
the operator to correct the issue
via Analyzer and disable all
functions until stored data in
corrupted area is changed.
Cycle Power and change the
Machine Setup data.
LSS CO RR UP T E EPRO M 9 977 The Gro un d M od ule is advi sin g that th e LS S mo dule h as det ec ted
faulty stored parameters.
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
FUNCTIONS LOCKED OUT -
GROUND MODULE SOFTWARE
VERSION IMPROPER
9979 Ground Module detects a disagreement with internal checks on the
version of software.
All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start)
Cycle power to clear the fault.
GROUND MODULE VLOW FET
FAILURE
9986 Ground Module has determined a hardware fault exists and is unable
to read high-sensing inputs.
All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start)
Cycle power to clear the fault.
1
Annotated DTCs do not flash a numeric code, sound an alarm, and are not stored in annotated DTCs in Logged Help queue (this applies to most DTCs < 0100).
Table 6-10. Fault Code Troubleshooting Information
Help Message DTC Condition Producing DTC
Control System Response or
Machine Condition
Corrective Action/
Operational Requirement
for Function Movement
and/or to Clear Fault