SECTION 6 - JLG CONTROL SYSTEM
6-68 – JLG Lift – 3121259
FUNCTIONS LOCKED OUT -
PLATFORM MODULE SOFT-
WARE VERSION IMPROPER
9910 The Ground Module software major version number does not match
the major version number of the platform software
The platform alarm sounds
continuously and, Creep mode
is active. If the Platform Mode is
active all Drive, Steer, and
Boom functions are disabled.
Platform Module needs repro-
grammed with correct version
of software.
FUNCTION LOCKED OUT - LSS
MODULE SOFTWARE VERSION
IMPROPER
9911 The Ground Module determines that the LSS software version is not
compatible with existing code.
The Ground Module sets the
Platform Load State to Over-
loaded
Cycle power to clear the fault.
CHASSIS TILT SENSOR NOT
GAIN CALIBRATED
9915 The tilt sensor gain calibration values recorded to flash memory dur-
ing manufacturing are not present
The Ground Module reports a
faulted chassis tilt angle of 90
degrees
Valid values must be present to
reset.
GROUND SENSOR REF VOLT-
AGE OUT OF RANGE
9919 The Ground Module has detected reference voltage is out of range
(Reference Voltage is between 2.3V and 2.7V).
If MACHINE SETUP Kubota
D1105 and ENGINE SHUTDOWN
ENABLED, then call for
engine shutdown and disable
engine start operations; other-
wise, no interlocks required.
Cycle power to clear the fault.
PLATFORM SENSOR REF VOLT-
AGE OUT OF RANGE
9920 The Platform Module detects that its reference voltage is out of range
and reports the fault to the Ground Module
If in Platform mode, Lift/Swing
and Drive are placed in Creep.
All other functions shall oper-
ate normally.
Cycle power to clear the fault.
GROUND MODULE FAIL-
URE:HIGH SIDE DRIVER CUT-
OUT FAULTY
9921 The engine is not running
The engine is not cranking
The Ground Module footswitch input (J7-15) is LOW
The machine is in Platform Mode
The Main Dump output (J2-13) is detected as HIGH via the analog
feedback 300ms after it is attempted to be activated during the one
time startup test of the Ground Module hardware shutoff circuitry
All Drive/Steer and Boom func-
tions except Tower Lift Down,
Lift Down, and Jib Lift Down are
disabled.
Cycle power to clear the fault.
PLATFORM MODULE FAILURE:
HWFS CODE 1
9922 The Platform Module detects faulty hardware No response required. Cycle power to clear the fault; if
faults remains, replace board.
GROUND MODULE FAILURE:
HWFS CODE 1
9923 The Ground Module detects faulty hardware. No response required. Cycle power to clear the fault; if
faults remains, replace board.
FUNCTIONS LOCKED OUT -
MACHINE NOT CONFIGURED
9924 The machine is powered up and no model has been selected yet in the
MACHINE SETUP menu
Display??? or NO MODEL at Ana-
lyzer MACHINE SETUP menu
MACHINE SETUP->MODEL
NUMBER
No other faults will be reported.
All machine functions are dis-
abled and the engine is not per-
mitted to start.
Cycle power to clear the fault.
CURRENT FEEDBACK GAINS
OUT OF RANGE
9944 One or more of the current feedback gains that are calculated and
written to flash memory during manufacturing are detected as
being out of range
A gain of 1 is used for the fac-
tory gain(s) that was out of
range; all functions are placed
in Creep mode.
Cycle power to clear the fault.
Table 6-10. Fault Code Troubleshooting Information
Help Message DTC Condition Producing DTC
Control System Response or
Machine Condition
Corrective Action/
Operational Requirement
for Function Movement
and/or to Clear Fault