Jlg 601S Service Manual User Manual Page 106

  • Download
  • Add to my manuals
  • Print
  • Page
    / 240
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 105
SECTION 3 - CHASSIS & TURNTABLE
3-66 – JLG Lift – 3120866
Failure Modes
Immediate Red Light
Action:
1. Recycle power to determine if the problem is inter-
mittent.
2. The input voltage must be greater than 10.5 Vdc.
3. Check wiring for any damage and correct.
4. Disconnect engine harness and actuator connnec-
tions.
5. If problem reoccurs return unit.
Green and either Amber light followed by a red light
or
then
Action:
1. Inspect and clean wiring connections.
2. Examine throttle linkage for any damage or bent
components and correct.
3. With linkage disconnected, check each potentiome-
ter for operation.
4. Reconnect linkage and reset each potentiometer for
correct operation.
5. If failure continues to occur, replace unit.
Only green light on and no actuator movement
Action:
1. Adjust trim potentiometers.
2. If problem continues, replace unit.
Page view 105