SECCIΓ“N 4 – PLUMA Y PLATAFORMA
3123348 – Elevador JLG – 4-35
VER DETALLE F
INTERRUP. PROXIMIDAD
PARA EVITAR DAΓ‘AR EL INTERRUPTOR DE PROXIMIDAD, INSTÁLELO Y AJÚSTELO LUEGO DE MONTAR EL BLOQUE DEL
INTERRUPTOR, COLOCAR EL RESORTE DE COMPRESIΓ“N Y APLICAR EL PAR DE APRIETE A LOS CABLES DE ACERO.
PARA AJUSTAR EL INTERRUPTOR DE PROXIMIDAD:
1. ENROSQUE EL INTERRUPTOR HASTA QUE TOQUE LA TRABA DE AJUSTE
2. DESENROSQUE EL INTERRUPTOR 1/8 Y 1/2 VUELTA PARA OBTENER EL RANGO DE DETECCIΓ“N ADECUADO.
3. AJUSTE LA CONTRATUERCA
INTERRUP. LÍMITE DE LARGO DE PLUMA PARA
ACTIVAR CUANDO LA PLUMA AΓ‰REA ESTÁ
EXTENDIDA 12" Β± 1,5" (1350SJP)
o 24" Β± 1,5" (1200SJP)
[30,5 cm Β± 3,8 cm (1350SJP)
o 60,96 cm Β± 3,8 cm (1200SJP)
VER DETALLE B
DETALLE B
DETALLE F
Figura 4-19. InstalaciΓ³n de los sensores e interruptores de la pluma o del aguilΓ³n – Hoja 4 de 4