SECTION 6 - JLG CONTROL SYSTEM
3121142 – JLG Lift – 6-41
OSC AXLE P SW OP/CL Displays status of oscillating axle pressure switch. (Displayed if OSCILLATING
AXLE = 1)
SKY WELDER YES/NO Displays the status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
SKY CUTTER YES/NO Displays the status of Sky Cutter selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
SKY GLAZIER YES/NO Displays the status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
SKY BRIGHT YES/NO Displays the status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
PIPE RACKS YES/NO Displays the status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
CAMERA MOUNT YES/NO Displays the status of Camera Mount selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
LOAD:
Not displayed if LOAD=NO, LENGTH=NO, and ANGLE=NO (machine digits =
0)
LENGTH OP /CL Displays measured length, NOTE: Not displayed if MODEL NUMBER = 7 or 8
ANGLE OP / CL Displays measured angle, NOTE: Not displayed if MODEL NUMBER = 7 or 8
WEIGHT XXXX% Percentage of maximum calibrated weight on the platform. An uncalibrated
load cell will read 1000% Displayed if LOAD is not 0 and LOAD TYPE is 0.
OK/OVERLOADED Displayed if LOAD is not 0 and LOAD TYPE is 1.
Table 6-5. Machine Diagnostics Parameters
Diagnostics Submenu
(Displayed on Analyzer
1
st
Line)
Parameter (Displayed on
Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description