Jlg 1350SJP Service Manual User Manual Page 377

  • Download
  • Add to my manuals
  • Print
  • Page
    / 554
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 376
SECTION 6 - JLG CONTROL SYSTEM
3121142 – JLG Lift – 6-1
SECTION 6. JLG CONTROL SYSTEM
6.1 INTRODUCTION
WHEN INSTALLING ANY NEW MODULE CONTROLLER ON THE MACHINE, IT
WILL BE NECESSARY TO PROGRAM THE CONTROLLER FOR THE PROPER
MACHINE CONFIGURATION, INCLUDING OPTIONS AND PROPERLY CALIBRATE
THE TILT SENSOR.
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRICAL/ELEC-
TRONIC COMPONENTS. SHOULD PRESSURE-WASHING BE UTILIZED TO WASH
AREAS CONTAINING ELECTRICAL/ELECTRONIC COMPONENTS, JLG INDUS-
TRIES, INC. RECOMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE COMPO-
NENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS ARE SPRAYED, SPRAYING
MUST NOT BE DIRECT AND BE FOR BRIEF TIME PERIODS TO AVOID HEAVY SAT-
URATION.
The JLG designed Control System is a 12 volt based control
unit installed on the boom lift.
The JLG Control System has reduced the need for exposed ter-
minal strips, diodes and trimpots and provides simplicity in
viewing and adjusting the various personality settings for
smooth control of: acceleration, deceleration, creep, min
speed, and max.-speed for all boom, drive, and steering func-
tions.
The main lift, swing, and drive are controlled by individual joy-
sticks, with steering being controlled by a rocker switch built
into the top the drive joystick. To activate Drive, Lift, and Swing
simply pull up on the slide lock location on the joystick and
move the handle into the direction desired.
The control system will control the voltage output to the
valves and pump, as programmed for smooth operation and
maximum cycle time. Ground control speeds for all boom
functions can also be programmed into the control system.
The JLG Control System controller has a built in LED to indicate
any faults. The system stores recent faults which may be
accessed for troubleshooting. Optional equipment includes a
soft touch system, head and tail lights, and ground alarm.
These options may be added later but must be programmed
into the control system when installed.
The Control System may be accessed utilizing a custom
designed, hand held analyzer (Analyzer Kit, JLG part no.
2901443) which will display two lines of information at a time,
by scrolling through the program.
Analyzer Display
Escape Key
To ret ur n ho me or ac cess pre vi -
ous menu
Enter Key
Stores and selects Top Level, Sub Level,
and item menus
Left & Right Arrow Keys
Used to move between Top Level, Sub
Level, and item menus
Up & Down Arrow Keys
Value Selector
Figure 6-1. Hand Held Analyzer
Page view 376
1 2 ... 372 373 374 375 376 377 378 379 380 381 382 ... 553 554

Comments to this Manuals

No comments