SECTION 6 - JLG CONTROL SYSTEM
3121142 – JLG Lift – 6-23
6.9 MACHINE PERSONALITY SETTINGS/FUNCTION
SPEEDS
NOTE: Personality settings can be adjusted within the adjustment
range in order to achieve optimum machine performance.
Table 6-3. Personality Ranges/Defaults
SUBMENU
(DISPLAYED ON
ANALYZER 1ST LINE)
PARAMETER
(DISPLAYED ON ANALYZER 2
ND
LINE)
DESCRIPTION RANGE
DEFAULT VALUES
TIME RANGE (SEC) (SEE
SECTION 6.10 FOR
MACHINE ORIENTATION
WHEN SETTING SPEEDS)
1200 1350 1200S 1350S
DRIVE: ACCEL X.Xs Displays/adjusts drive acceleration 0.1 to 5.0 sec 2.0 2.0
DECEL X.Xs Displays/adjusts drive deceleration 0.1 to 3.0 sec 1.3 1.3
MIN forward XX% Displays/adjusts minimum forward drive
speed
0 to 35% 1 1
MAX forward XXX% Displays/adjusts maximum forward drive
speed
0 to 100% 100 100 44-48 44-48
MIN reverse XX% Displays/adjusts minimum reverse drive speed 0 to 35% 1 1
MAX reverse XXX% Displays/adjusts maximum reverse drive speed 0 to 100% 100 100 44-48 44-48
ELEV. MAX XX% Displays/adjusts maximum drive speed
NOTE: used when elevation cutout switches are
limiting maximum speed
0 to 50% 25 25 93-104 93-104
CREEP MAX XX% Displays/adjusts maximum drive speed
NOTE: used when creep switch on pump pot is
active
0 to 50% 35 35 79-87 79-87
STEER: max SPEED XXX% Displays/adjusts maximum steer speed. 0 to 100% 100 100
MAIN LIFT: ACCEL X.Xs Displays/adjusts main lift acceleration 0.1 to 5.0 sec 1.0 1.0
DECEL X.Xs Displays/adjusts main lift deceleration 0.1 to 3.0 sec 1.0 1.0
MIN Up XX% Displays/adjusts minimum main lift up speed 0 to 60% 20 20
MAX UP XX% Displays/adjusts maximum main lift up speed 0 to 100% 50 50 75-100 75-100
MIN DOWN XX% Displays/adjusts minimum main lift down
speed
0 to 60% 10 10
MAX DOWN XXX% Displays/adjusts maximum main lift down
speed
0 to 100% 50 50 85-110 85-110
CREEP UP XX% Displays/adjusts maximum main lift up speed
NOTE: used when creep switch on pump pot is
active
0 to 65% 50 50
CREEP DOWN XX% Displays/adjusts maximum main lift down
speed
NOTE: used when creep switch on pump pot is
active
0 to 75% 45 45