SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
7-6 – JLG Lift – 3120895
AMP Mate-N-Lok
Follow the installation instructions.
DIN Connectors
This connector is typically used on hydraulic valves. Fol-
low the installation instructions.
Exclusions
A limited number of connectors do not benefit from dielec-
tric grease, or may be permanently damaged by applica-
tion. Dielectric grease may not be required in properly
sealed enclosures.
BRAD HARRISON / PHOENIX CONTACT M12
The connector uses gold contact material to resist corro-
sion and an o-ring seal for moisture integrity. If dielectric
grease is mistakenly applied to this connector system, the
low-force contacts cannot displace the grease to achieve
electrical contact. Once contaminated, there is no practi-
cal way to remove the dielectric grease (replacement of
female contacts required). The JLG Load Sensing System
and 1250AJP Rotary Angle Sensors are examples of com-
ponents with the M12 connector system.
Figure 7-6. Use of Seal Plugs