3120895 – JLG Lift – 3-197
DTC 1616- Microprocessor Failure -
interrupt
Engine Control Module
Check Condition- Key on
Fault Condition- Internal microprocessor error
MIL- On until code is cleared by technician
Adaptive- Disabled for the remainder of the key-on
cycle
Closed Loop- Enabled
Power Derate (level 2 until fault is cleared manually)
The ECM has checks that must be satisfied each time an
instruction is executed. Several different things can hap-
pen within the microprocessor that will cause this fault.
The ECM will reset itself in the event this fault is set, and
the MIL will be on until the code is cleared. This fault
should be erased after diagnosis by removing battery
power. It will not self-erase.
During this active fault, Power Derate (level 2) will be
enforced. When this is enforced, maximum throttle posi-
tion will be 20%. This is enforced until the fault is manually
cleared.